Powered by GoogleTranslate

Inspection Detail

Inspection: 110340387 - Kerr Mcgee Refining Corp. Cotton Valley Refinery

Inspection Information - Office: Baton Rouge Area Office

 

Inspection Nr: 110340387
Report ID: 0625700
Date Opened: 03/13/1990

Site Address:
Kerr Mcgee Refining Corp. Cotton Valley Refinery
Highway 7 South
Cotton Valley, LA 71018

Mailing Address:
P.O. Box 97, Cotton Valley, LA 71018

Union Status: Union

SIC:2911

NAICS: 0 


Inspection Type: Unprog Rel

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 05/29/1990

Emphasis:

Case Closed: 07/11/1990


Related Activity
Type Activity Nr Safety Health
Accident 360336366
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $1,620 $0 $0 $0 $0 $1,620
Current Penalty $1,134 $0 $0 $0 $0 $1,134
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260021 B06 I 06/06/1990 06/09/1990 $567 $810 $0 I - Informal Settlement  
2. 01002 Serious 19260850 E 06/06/1990 06/09/1990 $567 $810 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 514885
Event: 03/11/1990
Three employees killed in oil tank explosion

At about 2:10 p.m. on March 11, 1990, Employees #1, #2, and #3 had been using electric Skilsaws to cut and remove a damaged interior vapor barrier from a 55,000 barrel crude oil tank. They had just returned from a break, during which time the coppus ventilator had been turned off. Temperatures reached the mid-80s during the day, increasing the vapor concentration within the tank. An explosion fire occurred in which Employees #1, #2, and #3 suffered second- and third-degree burns, smoke inhalation, and concussions. All three died. The model #5125 Skilsaws were not approved for use in a class I atmosphere. The owner of the tank tested the atmosphere only once per day for percent lower exposure limit and oxygen. The accident was the result of using unapproved (for the location) equipment in a potentially flammable atmosphere.

Keywords: FLAMMABLE VAPORS, WORK RULES, OIL TANK, CIRCULAR SAW, ELECTRIC SAW, EXPLOSION, SMOKE INHALATION, VENTILATION, FIRE, CONSTRUCTION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 110340387 Occupation Not Listed
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close