Powered by GoogleTranslate

Inspection Detail

Inspection: 110315777 - Cbi Na-Con, Inc.

Inspection Information - Office: Houston North Area Office

 

Inspection Nr: 110315777
Report ID: 0626600
Date Opened: 04/16/1990

Site Address:
Cbi Na-Con, Inc.
12211 Port Road
Seabrook, TX 77586

Mailing Address:
P. O. Box 41146, Houston, TX 77241

Union Status: NonUnion

SIC:1791

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 04/23/1990

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 12/26/1990


Related Activity
Type Activity Nr Safety Health
Accident 360971824
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 4 6
Current Violations 4 4
Initial Penalty $1,260 $0 $0 $0 $0 $1,260
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260021 B02 05/04/1990 05/09/1990 $630 $630 $0 06/01/1990 R - Review Commission Citation has been deleted.
2. 01002 Serious 19260550 A15 I 05/04/1990 05/09/1990 $630 $630 $0 06/01/1990 R - Review Commission Citation has been deleted.
3. 02001 Other 19100020 G01 05/04/1990 10/31/1990 $0 $0 $0 06/01/1990 R - Review Commission  
4. 02002 Other 19100020 G01 II 05/04/1990 10/31/1990 $0 $0 $0 06/01/1990 R - Review Commission  
5. 02003 Other 19100020 G01 III 05/04/1990 10/31/1990 $0 $0 $0 06/01/1990 R - Review Commission  
6. 02004 Other 19100020 G02 05/04/1990 10/31/1990 $0 $0 $0 06/01/1990 R - Review Commission  

Investigation Summary

Investigation Nr: 14465645
Event: 04/12/1990
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU BOOM

A four-person crew was moving a pallet supporting a pump motor to a different location so that a sea container could be placed where the pallet had been. A 12.4-kilovolt overhead power line that was 11.6 meters above the ground was located over the pallet. One of the employees rigged the load to a Lorain 45-metric-ton crane and signaled the operator to move the load. The crane operator moved the boom. The tip of the boom, which had been extended 11.7 meters, contacted the power line. The employee who had signaled the crane operator was holding a chain sling when the boom contacted the power line. He was electrocuted. The crane operator saw the injured employee fall to the ground and thought he had been struck by the load. The operator moved the load immediately and turned the crane off. A helper, who had been holding the wooden pallet at the time of the accident, was not injured.

Keywords: OVERHEAD POWER LINE, ELECTRICAL, BOOM, CRANE BOOM, ELECTROCUTED, E GI IA, CRANE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 110315777 Fatality Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.