Inspection Detail
Inspection: 110289485 - G. B. Manufacturing
Inspection Information - Office: Toledo Area Office
Site Address:
G. B. Manufacturing
100 Adams St.
Delta, OH 43515
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3714
NAICS: 0
Inspection Type: Complaint
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 09/08/1989
Emphasis:
Case Closed: 11/10/1989
Type | Activity Nr | Safety | Health |
---|---|---|---|
Complaint | 72817992 | Yes |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | 1 | 3 | ||
Current Violations | 1 | 1 | 1 | 3 | ||
Initial Penalty | $600 | $0 | $1,200 | $0 | $0 | $1,800 |
Current Penalty | $300 | $0 | $600 | $0 | $0 | $900 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19100217 B04 I | 10/04/1989 | 10/07/1989 | $300 | $600 | $0 | I - Informal Settlement | ||
2. | 02001 | Repeat | 19100217 C01 I | 10/04/1989 | 10/07/1989 | $600 | $1,200 | $0 | I - Informal Settlement | ||
3. | 03001 | Other | 19100217 G01 | 10/04/1989 | 10/11/1989 | $0 | $0 | $0 | - |
Investigation Summary
Employee #1 was operating a small power punch press and became caught in the unguarded point of operation. Employee #1 suffered partial amputation of her finger.
Keywords: AMPUTATED, POWER PRESS, FINGER, CAUGHT BY, POINT OF OPERATION, PRESS OPERATOR, PUNCH PRESS, UNGUARDED
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 110289485 | Non Hospitalized injury | Amputation | Occupation not reported |