Inspection Detail
Inspection: 110269842 - Tiny Tom, The Chimney Sweep
Inspection Information - Office: Toledo Area Office
Site Address:
Tiny Tom, The Chimney Sweep
1010 Fort Street
Bowling Green, OH 43402
Mailing Address:
733 S. Byrne Road, Toledo, OH 43609
Union Status: NonUnion
SIC:7349
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 05/18/1992
Emphasis:
Case Closed: 05/18/1992
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360422497 |
Investigation Summary
AN EMPLOYEE WAS TUCK POINTING A CHIMNEY ON A RESIDENCE. HE WAS USING AN ALUMINUM LADDER ABOUT 30 FEET IN LENGTH. WHEN THE EMPLOYEE MOVED THE LADDER WHILE IT WAS STILL EXTENDED, IT CONTACTED AN OVERHEAD POWER LINE THAT WAS LOCATED BEHIND THE EMPLOYEE. HE WAS ELECTROCUTED.
Keywords: OVERHEAD POWER LINE, ELECTRICAL, ELECTROCUTED, LADDER, METAL LADDER, E GI IB
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 110269842 | Fatality | Electric Shock | Occupation not reported |