Inspection Detail
Inspection: 110121704 - Sexton Plumbing Dba Rodney Sexton
Inspection Information - Office: Birmingham Area Office
Site Address:
Sexton Plumbing Dba Rodney Sexton
3600 10th Avenue North
Birmingham, AL 35234
Mailing Address:
P.O. Box 669, Pinson, AL 35126
Union Status: NonUnion
SIC:1711
NAICS: 0
Inspection Type: Unprog Rel
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 11/26/1991
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 02/07/1992
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360711618 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | 2 | |||
Current Violations | 1 | 1 | 2 | |||
Initial Penalty | $125 | $0 | $0 | $0 | $0 | $125 |
Current Penalty | $125 | $0 | $0 | $0 | $0 | $125 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19260059 G01 | 12/31/1991 | 01/07/1992 | $125 | $125 | $0 | - | ||
2. | 02001 | Other | 19260405 A02 II | 12/31/1991 | 01/03/1992 | $0 | $0 | $0 | - |
Investigation Summary
Employee #1 was burning a ladder and cage off a 55 gallon paint storage tank that had been damaged during a fire. The employee had made three cuts near the top of the tank when an explosion occurred. The tank was hurled several feet through the air and landed on the ladder side. Employee #1 was killed.
Keywords: STORAGE TANK, EXPLOSION, CONSTRUCTION, CUTTING AND BURNING
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 110121704 | Occupation Not Listed |