Inspection Detail
Inspection: 110108354 - Phoenix Refrigeration
Inspection Information - Office: Atlanta East Area Office
Site Address:
Phoenix Refrigeration
709 Sigman Road
Conyers, GA 30208
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3585
NAICS: 0
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 08/15/1991
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 08/27/1991
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 901171579 | Yes |
Investigation Summary
Employees #1 and #2 were performing a quality control check on a gas-fired furnace when a fire and explosion occurred. The employees sustained 2nd- and 3rd-degree burns to their arms, hands, and faces.
Keywords: BURN, FURNACE, FIRE, EXPLOSION, ARM, FACE, HAND
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 110108354 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported | ||
| 2 | 110108354 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported |
Translate