Inspection Detail
Inspection: 110107661 - Popper'S Saloon
Inspection Information - Office: Atlanta West Area Office
Site Address:
Popper'S Saloon
2501 Delk Road, Se
Marietta, GA 30067
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:5812
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 11/26/1991
Emphasis:
Case Closed: 11/03/1992
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360145916 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $1,500 | $0 | $0 | $0 | $0 | $1,500 |
| Current Penalty | $750 | $0 | $0 | $0 | $0 | $750 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 5A0001 | 12/04/1991 | 01/04/1992 | $750 | $1,500 | $0 | I - Informal Settlement |
Investigation Summary
Employee #1 entered a grease trap that was approximately 5 ft deep and contained 4 ft of liquid to unclog or clean it out. The underground trap was accessed by a 30 in. manhole at ground level. Employee #1 had used approximately 1 gallon of a sulfuric acid-based drain cleaner. When Employee #1 entered the grease trap, he was overcome by what was most likely hydrogen sulfide gas. Employee #1 was unconscious when he was rescued. He did not regain consciousness and died.
Keywords: UNCONSCIOUSNESS, CONFINED SPACE, HYDROGEN SULFIDE, TOXIC FUMES, OVEREXPOSURE
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 110107661 | Fatality | Other | Occupation not reported |
Translate