Powered by GoogleTranslate

Inspection Detail

Inspection: 110105970 - Accu-Rite Machine Co.

Inspection Information - Office: Atlanta East Area Office

 

Inspection Nr: 110105970
Report ID: 0418100
Date Opened: 05/28/1991

Site Address:
Accu-Rite Machine Co.
4301 Evans -To- Locks Road
Evans, GA 30809

Mailing Address:
3757 Old Savannah Road, Blythe, GA 30806

Union Status: NonUnion

SIC:3599

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: Y

Ownership: Private

Safety/Health: Safety

Close Conference: 05/31/1991

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 04/18/1995


Related Activity
Type Activity Nr Safety Health
Accident 360958961
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 4
Current Violations 4 4
Initial Penalty $6,000 $0 $0 $0 $0 $6,000
Current Penalty $6,000 $0 $0 $0 $0 $6,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100252 A01 II 08/12/1991 08/15/1991 $1,500 $1,500 $0 09/09/1991 F - Formal Settlement  
2. 01002 Serious 19100252 A02 XIVD 08/12/1991 08/15/1991 $1,500 $1,500 $0 09/09/1991 F - Formal Settlement  
3. 01003 Serious 19100252 B01 I 08/12/1991 08/15/1991 $1,500 $1,500 $0 09/09/1991 F - Formal Settlement  
4. 01004A Serious 19101200 E01 08/12/1991 09/27/1991 $1,500 $1,500 $0 09/09/1991 F - Formal Settlement  
5. 01004B Serious 19101200 G01 08/12/1991 09/23/1991 $0 $0 $0 09/09/1991 F - Formal Settlement  
6. 01004C Serious 19101200 H 08/12/1991 09/23/1991 $0 $0 $0 09/09/1991 F - Formal Settlement  

Investigation Summary

Investigation Nr: 597260
Event: 05/26/1991
Employees burned during solvent recovery system explosion

Employee #3, #4, #5, and #6 were preparing to remove an aftercooler unit from a solvent recovery system, manufactured by Dedert Corp., for maintenance. Employees #3, #4, and #6 were approximately 17 ft 7 in. above the adjacent ground level, removing the bolts from the aftercooler unit. Employee #4 was using an oxygen and acetylene torch to cut off bolts that were difficult to remove. Employee #3 was on firewatch on the ground level. Employees #1 and #2 were watching the work from ground level, directly in front of a blower unit that was part of the recovery system. When the crane operator put tension on the valve for support to remove the unit, a seal was broken on the butterfly valve that separated the aftercooler from the main duct to adsorber beds. Employee #4 lit the torch and a fireball explosion occurred, injuring the six employees. Employee #1 and #3 sustained 2nd- and 3rd-degree burns and were in critical condition. Employees #2 and #4 sustained 2nd-degree burns and were in serious condition. Employees #5 and #6 sustained minor injuries. Improper purging of the system allowed toluene and lactol spirits vapors to remain and accumulate. Hot work permit procedures were not followed. The system was not effectively isolated from the hot work. Five of the six valves between the aftercoolers and adsorbers were open.

Keywords: FLAMMABLE VAPORS, WORK RULES, TOLUENE, EXPLOSION, BURN, MAINTENANCE, VAPOR, ACETYLENE TORCH, FIRE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 110105970 Hospitalized injury Burn/Scald(Heat) Occupation not reported
2 110105970 Hospitalized injury Burn/Scald(Heat) Occupation not reported
3 110105970 Hospitalized injury Burn/Scald(Heat) Occupation not reported
4 110105970 Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.