Inspection Detail
Inspection: 110105962 - Ranger American Of Georgia, Inc.
Inspection Information - Office: Atlanta East Area Office
Site Address:
Ranger American Of Georgia, Inc.
4301 Evans To Lock Road
Evans, GA 30809
Mailing Address:
P.O. Box 1372, Augusta, GA 30903
Union Status: NonUnion
SIC:2732
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: Y
Ownership: Private
Safety/Health: Safety
Close Conference: 05/31/1991
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 09/16/1991
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360958961 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 4 | 4 | ||||
| Current Violations | 4 | 4 | ||||
| Initial Penalty | $18,000 | $0 | $0 | $0 | $0 | $18,000 |
| Current Penalty | $14,000 | $0 | $0 | $0 | $0 | $14,000 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001A | Serious | 19100252 A02 IV | 07/31/1991 | 08/20/1991 | $3,500 | $4,500 | $0 | I - Informal Settlement | ||
| 2. | 01001B | Serious | 19100252 A02 XIIID | 07/31/1991 | 08/20/1991 | $0 | $0 | $0 | - | ||
| 3. | 01001C | Serious | 19100252 A02 XIVA | 07/31/1991 | 08/20/1991 | $0 | $0 | $0 | - | ||
| 4. | 01001D | Serious | 19100252 A02 XIVE | 07/31/1991 | 08/20/1991 | $0 | $0 | $0 | - | ||
| 5. | 01002A | Serious | 19100252 A02 VIC | 07/31/1991 | 08/20/1991 | $3,500 | $4,500 | $0 | I - Informal Settlement | ||
| 6. | 01002B | Serious | 19100252 A02 VII | 07/31/1991 | 08/03/1991 | $0 | $0 | $0 | - | ||
| 7. | 01002C | Serious | 19100252 A02 VIII | 07/31/1991 | 08/20/1991 | $0 | $0 | $0 | - | ||
| 8. | 01003 | Serious | 19100252 A03 II | 07/31/1991 | 08/20/1991 | $3,500 | $4,500 | $0 | I - Informal Settlement | ||
| 9. | 01004A | Serious | 19101200 E01 II | 07/31/1991 | 08/20/1991 | $3,500 | $4,500 | $0 | I - Informal Settlement | ||
| 10. | 01004B | Serious | 19101200 E02 I | 07/31/1991 | 08/20/1991 | $0 | $0 | $0 | - | ||
| 11. | 01004C | Serious | 19101200 E02 III | 07/31/1991 | 08/20/1991 | $0 | $0 | $0 | - | ||
| 12. | 01004D | Serious | 19101200 H02 III | 07/31/1991 | 08/20/1991 | $0 | $0 | $0 | - |
Investigation Summary
Employee #3, #4, #5, and #6 were preparing to remove an aftercooler unit from a solvent recovery system, manufactured by Dedert Corp., for maintenance. Employees #3, #4, and #6 were approximately 17 ft 7 in. above the adjacent ground level, removing the bolts from the aftercooler unit. Employee #4 was using an oxygen and acetylene torch to cut off bolts that were difficult to remove. Employee #3 was on firewatch on the ground level. Employees #1 and #2 were watching the work from ground level, directly in front of a blower unit that was part of the recovery system. When the crane operator put tension on the valve for support to remove the unit, a seal was broken on the butterfly valve that separated the aftercooler from the main duct to adsorber beds. Employee #4 lit the torch and a fireball explosion occurred, injuring the six employees. Employee #1 and #3 sustained 2nd- and 3rd-degree burns and were in critical condition. Employees #2 and #4 sustained 2nd-degree burns and were in serious condition. Employees #5 and #6 sustained minor injuries. Improper purging of the system allowed toluene and lactol spirits vapors to remain and accumulate. Hot work permit procedures were not followed. The system was not effectively isolated from the hot work. Five of the six valves between the aftercoolers and adsorbers were open.
Keywords: FLAMMABLE VAPORS, WORK RULES, TOLUENE, EXPLOSION, BURN, MAINTENANCE, VAPOR, ACETYLENE TORCH, FIRE
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 110105962 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported | ||
| 2 | 110105962 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported |
Translate