Powered by GoogleTranslate

Inspection Detail

Inspection: 110103967 - Chapman Masonry

Inspection Information - Office: Atlanta East Area Office

 

Inspection Nr: 110103967
Report ID: 0418100
Date Opened: 09/13/1990

Site Address:
Chapman Masonry
1835 Jenny Lane
Lithia Springs, GA 30057

Mailing Address:
10180 Jones Bridge Road, Alpharetta, GA 30201

Union Status: NonUnion

SIC:1741

NAICS: 0 


Inspection Type: Referral

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/13/1990

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 11/05/1990


Related Activity
Type Activity Nr Safety Health
Referral 901178681 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 11 5 16
Current Violations 11 5 16
Initial Penalty $4,260 $0 $0 $120 $0 $4,380
Current Penalty $4,260 $0 $0 $120 $0 $4,380
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260020 B01 09/28/1990 10/24/1990 $420 $420 $0 -  
2. 01002 Serious 19260021 B02 09/28/1990 10/24/1990 $420 $420 $0 -  
3. 01003 Serious 19260100 A 09/28/1990 10/04/1990 $420 $420 $0 -  
4. 01004 Serious 19260250 A01 09/28/1990 10/04/1990 $180 $180 $0 -  
5. 01005 Serious 19260451 A03 09/28/1990 10/04/1990 $420 $420 $0 -  
6. 01006 Serious 19260451 A10 09/28/1990 10/04/1990 $420 $420 $0 -  
7. 01007 Serious 19260451 A14 09/28/1990 10/04/1990 $300 $300 $0 -  
8. 01008 Serious 19260451 A15 09/28/1990 10/04/1990 $420 $420 $0 -  
9. 01009 Serious 19260451 D03 09/28/1990 10/04/1990 $420 $420 $0 -  
10. 01010 Serious 19260451 D04 09/28/1990 10/04/1990 $420 $420 $0 -  
11. 01011 Serious 19260451 D10 09/28/1990 10/04/1990 $420 $420 $0 -  
12. 02001 Other 19030002 A01 09/28/1990 10/04/1990 $60 $60 $0 -  
13. 02002 Other 19040002 A 09/28/1990 10/04/1990 $60 $60 $0 -  
14. 02003 Other 19260059 E01 09/28/1990 10/24/1990 $0 $0 $0 -  
15. 02004 Other 19260059 G01 09/28/1990 10/24/1990 $0 $0 $0 -  
16. 02005 Other 19260059 H 09/28/1990 10/24/1990 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 596742
Event: 09/13/1990
Six employees injured when scaffold collapses

At 8:35 a.m. on September 13, 1990, Employees #1 through #6 were working on tubular welded frame scaffolding at a single-family house under construction. The employees were laying brick. The scaffolding was approximately 20 feet high. It had rained heavily the night before. The scaffold tipped over, injuring all six employees. The company had no safety program (1926.20(b)(1)), no training (1926.21(b)(2)), no hard hats (1926.100(a)), no competent person (1926.451(a)(3)), an inadequate work platform (1926.451(a)(10)), unacceptable planking end extension (1926.451(a)(14)), not plumb (1926.451(a)(15)), inadequate cross bracing (1926.451(d)(3)), inadequate footing (1926.451(d)(4)), and no guardrails (1926.451(d)(10)).

Keywords: HARD HAT, WORK RULES, CONSTRUCTION, SCAFFOLD COLLAPSE, UNTRAINED, WORK PLATFORM, UNGUARDED, OVERTURN

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 110103967 Non Hospitalized injury Cut/Laceration Occupation not reported
2 110103967 Hospitalized injury Fracture Occupation not reported
3 110103967 Hospitalized injury Cut/Laceration Occupation not reported
4 110103967 Non Hospitalized injury Cut/Laceration Occupation not reported
5 110103967 Non Hospitalized injury Fracture Occupation not reported
6 110103967 Non Hospitalized injury Bruise/Contus/Abras Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.