Inspection Detail
Inspection: 110094083 - Pcr, Inc.
Inspection Information - Office: Jacksonville Area Office
Site Address:
Pcr, Inc.
5002 Sperry Drive
Gainesville, FL 32602
Mailing Address:
P.O. Box 1466, Gainesville, FL 32602
Union Status: NonUnion
SIC:2819
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 07/29/1994
Emphasis:
Case Closed: 01/30/1995
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360817761 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | 2 | |||
Current Violations | 1 | 1 | 2 | |||
Initial Penalty | $1,625 | $0 | $0 | $0 | $0 | $1,625 |
Current Penalty | $1,625 | $0 | $0 | $0 | $0 | $1,625 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19100253 B04 III | 10/11/1994 | 10/14/1994 | $1,625 | $1,625 | $0 | - | ||
2. | 02001 | Other | 19100147 C04 II | 10/11/1994 | 11/29/1994 | $0 | $0 | $0 | - |
Investigation Summary
On June 17, 1994, Employee #1 of PCR, Inc., was given the task of transferring trichlorosilane (TCS) from a tanker that had arrived that morning to the pressure vessel in which the company stored the TCS. After emptying the TCS from the tanker, he began manifolding the line. By doing this, he increased the line pressure to about 40 psig. The transfer hose broke and a backflow of about 1,038 gallons of TCS occurred. This resulted in a large cloud of silicon dioxide and hydrochloric acid. No employees were injured as a result of this chemical release.
Keywords: HYDROCHLORIC ACID, HOSE, CHEMICAL VAPOR, ACCIDENTAL DISCHARGE
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 110094083 | Occupation Not Listed |