Inspection Detail
Inspection: 110064615 - Ethicon, Inc.
Inspection Information - Office: Atlanta East Area Office
Site Address:
Ethicon, Inc.
70 Clarksville Hwy
Cornelia, GA 30531
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3842
NAICS: 0
Inspection Type: Unprog Rel
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 12/07/1990
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 02/08/1991
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360450738 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $640 | $0 | $0 | $0 | $0 | $640 |
| Current Penalty | $640 | $0 | $0 | $0 | $0 | $640 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100305 J01 I | 12/28/1990 | 12/31/1990 | $640 | $640 | $0 | - |
Investigation Summary
TWO EMPLOYEES WERE REINSULATING A DE-AERATOR LOCATED ON A SUSPENDED CATWALK AND PLATFORM IN A BOILER ROOM. AS ONE OF THE EMPLOYEES CLIMBED BEHIND THE DE-AERATOR, WHICH WAS ABOUT 12 INCHES FROM THE WALL TO ITS INSULATION, HE CONTACTED A SOCKET-TYPE LIGHTING FIXTURE. THE SOCKET CONTAINED A BROKEN LIGHT BULB, WITH THE BARE FILAMENT PROTRUDING, AND THE FIXTURE WAS ENERGIZED. THE EMPLOYEE WAS ELECTROCUTED.
Keywords: E GI V, ELECTRICAL, ELECTROCUTED, LIGHTING FIXTURE, UNGUARDED LIVE PARTS
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 110064615 | Occupation Not Listed |
Translate