Powered by GoogleTranslate

Inspection Detail

Inspection: 109949503 - Par Par Contracting Corp.

Inspection Information - Office: Queens District Office

 

Inspection Nr: 109949503
Report ID: 0215600
Date Opened: 01/04/1995

Site Address:
Par Par Contracting Corp.
Fresh Pond Road & Grove Street
Ridgewood, NY 11385

Mailing Address:
78 14th Street, Brooklyn, NY 11215

Union Status: NonUnion

SIC:1795

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 06/02/1995

Emphasis: L:Gutreh

Case Closed: 07/03/1996


Related Activity
Type Activity Nr Safety Health
Accident 360397947
Referral 902649433 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $0 $0 $20,000 $0 $0 $20,000
Current Penalty $0 $0 $7,500 $0 $0 $7,500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Repeat 19260021 B02 06/22/1995 06/27/1995 $4,000 $10,000 $0 07/14/1995 J - ALJ Decision  
2. 01002 Repeat 19260100 A 06/22/1995 06/27/1995 $3,500 $10,000 $0 07/14/1995 J - ALJ Decision  

Investigation Summary

Investigation Nr: 170117543
Event: 01/04/1995
Employee is killed when he falls with suspended ceiling

Employee #1, a foreman, was on top of a plaster ceiling that was suspended from the roof by black iron. He was cutting the vertical metal supports with an oxygen and acetylene torch when a section of the ceiling he was standing on, approximately 90 ft by 50 ft, fell approximately 30 ft to the floor. The employee suffered internal injuries and died from internal bleeding.

Keywords: LOSS OF BLOOD, SUSPENDED CEILING, CEILING, CONSTRUCTION, UNSTABLE SURFACE, FALL, FALL PROTECTION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 109949503 Fatality Cut/Laceration Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close