Powered by GoogleTranslate

Inspection Detail

Inspection: 109856583 - Foundations Addition

Inspection Information - Office: Hartford Area Office

 

Inspection Nr: 109856583
Report ID: 0112000
Date Opened: 07/06/1998

Site Address:
Foundations Addition
81 Conantville Road
Mansfield Center, CT 06250

Mailing Address:
464 Strong Road, South Windsor, CT 06074

Union Status: NonUnion

SIC:1771

NAICS: 0 


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 07/23/1998

Emphasis:

Case Closed: 04/05/1999


Related Activity
Type Activity Nr Safety Health
Referral 901743641 Yes
Referral 901743708 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $3,000 $0 $0 $0 $0 $3,000
Current Penalty $1,500 $0 $0 $0 $0 $1,500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260020 B02 09/23/1998 11/10/1998 $750 $1,500 $0 I - Informal Settlement  
2. 01002A Serious 19260055 A 09/23/1998 11/10/1998 $750 $1,500 $0 I - Informal Settlement  
3. 01002B Serious 19260055 B 09/23/1998 11/10/1998 $0 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 200080174
Event: 07/03/1998
Employee overcome by carbon monoxide from propane saw

On July 3, 1998, Employee #1 and a coworker were using a propane-powered concrete cutting saw in an unventilated basement when they were overcome by carbon monoxide. The local fire department responded to the 911 call and transported the workers to Windham Hospital. They were then flown by helicopter to Norwich for treatment in a hyperbaric chamber. Approximately 30 minutes after the saw had been turned of, fire department personnel reported a carbon monoxide reading of 200 ppm.

Keywords: VENTILATION, WORK RULES, CONSTRUCTION, INHALATION, SAW, EXHAUST FUMES, CHEMICAL VAPOR, OVEREXPOSURE, CARBON MONOXIDE, CHEMICAL

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 109856583 Hospitalized injury Asphyxia Concrete and terrazzo finishers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.