Powered by GoogleTranslate

Inspection Detail

Inspection: 109680884 - Fibercom Data Services, Inc.

Inspection Information - Office: Tampa Area Office

 

Inspection Nr: 109680884
Report ID: 0420600
Date Opened: 01/23/1995

Site Address:
Fibercom Data Services, Inc.
160 Petty Circle
Titusville, FL 32796

Mailing Address:
6367 All Americal Blvd., Orlando, FL 32810

Union Status: NonUnion

SIC:1623

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 03/06/1995

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 03/31/1995


Related Activity
Type Activity Nr Safety Health
Accident 361979941
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 4
Current Violations 4 4
Initial Penalty $0 $0 $0 $1,750 $0 $1,750
Current Penalty $0 $0 $0 $1,750 $0 $1,750
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 19040002 A 03/09/1995 03/22/1995 $0 $0 $0 -  
2. 01002 Other 19040002 B02 03/09/1995 03/22/1995 $0 $0 $0 -  
3. 01003 Other 19040008 03/09/1995 03/14/1995 $1,750 $1,750 $0 -  
4. 01004 Other 19100268 C 03/09/1995 04/11/1995 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 14336044
Event: 01/20/1995
ELECTRIC SHOCK - DIRECT CONTACT WITH OVERHEAD LINE

A communications worker was installing a cable television cable on a joint-use utility pole. The employee, who was wearing pole climbers and a body belt, was working from the pole. A 7620-volt overhead power line located about 2.7 meters (9 feet) above the employee was supported by an insulator on the pole. While he was working, the insulator broke, allowing the power line to fall onto him. The employee was electrocuted. Upon investigation, the metal bracket holding the insulator to the pole was found to be badly rusted and corroded at the point where it failed.

Keywords: OVERHEAD POWER LINE, ELECTRICAL, CABLE TV WORK, E TC, INSULATOR, ELECTROCUTED, EQUIPMENT FAILURE, UTILITY POLE, COMMUNICATION WORKER

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 109680884 Fatality Electric Shock Misc. electrical & electronic equipment repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.