Powered by GoogleTranslate

Inspection Detail

Inspection: 109669408 - Spd Contracting, Inc.

Inspection Information - Office: Fort Lauderdale Area Office

 

Inspection Nr: 109669408
Report ID: 0418800
Date Opened: 03/04/1995

Site Address:
Spd Contracting, Inc.
800 Claughton Island Dr
Miami, FL 33128

Mailing Address:
4960 Sw 52nd St, Suite 407, Davie, FL 33314

Union Status: NonUnion

SIC:1742

NAICS: 0 


Inspection Type: Unprog Rel

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 03/20/1995

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 03/20/1995


Related Activity
Type Activity Nr Safety Health
Accident 361081862

Investigation Summary

Investigation Nr: 820720
Event: 03/04/1995
Three employees killed in fall from overloaded platform

On March 4, 1995, Employees #1, #2, and #3 were working on an elevated work platform. The platform had been modified by adding extensions to one end and using aluminum cantilevers to fit the design of the building. The work platform gave way because of overloading. Employees #1, #2, and #3 fell and died.

Keywords: WORK RULES, OVERLOADED, ELEVATED WORK PLAT, CONSTRUCTION, FALL, FALL PROTECTION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 109669408 Occupation Not Listed
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.