Powered by GoogleTranslate

Inspection Detail

Inspection: 109645465 - C & J Associates

Inspection Information - Office: Wilmington Area Office

 

Inspection Nr: 109645465
Report ID: 0317020
Date Opened: 05/10/1990

Site Address:
C & J Associates
Route 13
Minquandale, DE 19720

Mailing Address:
P. O. Box 628, New Castle, DE 19720

Union Status: NonUnion

SIC:2421

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 05/11/1990

Emphasis:

Case Closed: 09/11/1990


Related Activity
Type Activity Nr Safety Health
Accident 360337828
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 3 7
Current Violations 4 3 7
Initial Penalty $1,890 $0 $0 $0 $0 $1,890
Current Penalty $1,890 $0 $0 $0 $0 $1,890
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 5A0001 07/24/1990 09/10/1990 $420 $420 $0 -  
2. 01002 Serious 19100147 C01 07/24/1990 09/10/1990 $490 $490 $0 -  
3. 01003 Serious 19100303 B01 07/24/1990 07/27/1990 $490 $490 $0 -  
4. 01004 Serious 19100303 F 07/24/1990 07/27/1990 $490 $490 $0 -  
5. 02001A Other 19040002 A 07/24/1990 07/27/1990 $0 $0 $0 -  
6. 02001B Other 19040005 B 07/24/1990 07/27/1990 $0 $0 $0 -  
7. 02002 Other 19100022 A01 05/10/1990 08/10/1990 $0 $0 $0 -  
8. 02003 Other 19100095 D01 07/24/1990 09/10/1990 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 14317846
Event: 05/10/1990
ELECTRIC SHOCK - DIRECT CONTACT WITH ENERGIZED PARTS

An equipment operator was using a front-end loader to load wood chips into a hopper. The hopper fed a wood chip separator. The machine jammed, so the employee got off his loader to free it. He turned off the wood separator and hopper and then grabbed a 240-volt cable that was still energized. He was electrocuted. The cable had been damaged by rubbing against a conveyor belt. A portable generator supplied power to the equipment.

Keywords: E GI V, ELEC INSULATION, ELECTRICAL, ELECTRIC CABLE, ELECTROCUTED

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 109645465 Fatality Electric Shock Miscellaneous material moving equipment operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.