Powered by GoogleTranslate

Inspection Detail

Inspection: 109472225 - Chandler Interiors, Inc.

Inspection Information - Office: Atlanta West Area Office

 

Inspection Nr: 109472225
Report ID: 0418200
Date Opened: 09/30/1992

Site Address:
Chandler Interiors, Inc.
11 South West Upper Riverdale Road
Riverdale, GA 30247

Mailing Address:
4860 Crystal Lake Court, Kennesaw, GA 30144

Union Status: NonUnion

SIC:1742

NAICS: 0 


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/30/1992

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 08/06/1994


Related Activity
Type Activity Nr Safety Health
Referral 901537944 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 2
Current Violations 1 1 2
Initial Penalty $1,500 $0 $300 $0 $0 $1,800
Current Penalty $1,500 $0 $300 $0 $0 $1,800
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19261053 B01 11/16/1992 12/10/1992 $1,500 $1,500 $0 11/20/1992 J - ALJ Decision  
2. 02001 Repeat 19260059 E01 11/16/1992 11/30/1992 $300 $300 $0 11/20/1992 J - ALJ Decision  

Investigation Summary

Investigation Nr: 1000710
Event: 09/21/1992
Employee in coma after ladder falls into air shaft

At 3:00 p.m. on September 18, 1992, Employee #1 was using an aluminum extension ladder to descend 12' 9" from a roof line to the grating on which the ladder rested. Employee #1 was on the third or fourth rung when the grating gave way and he fell approximately 29 to 30 ft into an air shaft that was 20 1/2 ft deep by 15 ft long by 4 ft wide. He suffered severe head injuries, which required brain surgery and hospitalization, and remains in an induced coma. The air shaft was covered by standard grating supported by an angle iron that was anchored with two red head bolts that appeared to be approximately 1/2 in. in diameter. The bolts sheared off, causing the angle iron grating and the ladder, which was not secured at the top, to fall into the shaft. Prior to being placed at the location from which it fell, the ladder had been used near the center of the roof and extended through an area not yet decked; the ladder was tied off at that location. When the steel crew needed to complete the decking, the ladder was moved to the northwest corner and placed on the grating with its top wedged against the roof edge which met with a wall that extended from the roof at a 90 degree angle. Causal factors include the ladder being placed on an unstable surface and not being tied off at the top. The investigation revealed that employees of the general contractor, employees of the drywall crew, and the steel workers had all used the ladder while it was in that position.

Keywords: BOLT, SHEARED, DESCENDING, FALL, UNSECURED, METAL LADDER, EXTENSION LADDER, CONSTRUCTION, UNSTABLE SURFACE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 109472225 Occupation Not Listed
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close