Inspection Detail
Inspection: 109421412 - Dutch Harbor Seafood, Ltd.
Inspection Information - Office: Washington Area Office
Site Address:
Dutch Harbor Seafood, Ltd.
Pier 91, Port Of Seattle
Seattle, WA 98053
Mailing Address:
15400 Ne 90th Street, Redmond, WA 98053
Union Status: NonUnion
SIC:3731
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 12/20/1991
Emphasis: L:Ship
Case Closed: 12/02/1992
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 4 | 2 | 1 | 7 | ||
Current Violations | 5 | 1 | 1 | 7 | ||
Initial Penalty | $4,500 | $42,000 | $0 | $0 | $0 | $46,500 |
Current Penalty | $4,400 | $14,200 | $0 | $0 | $0 | $18,600 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19150007 A01 | 12/23/1991 | 12/27/1991 | $880 | $1,125 | $0 | 01/15/1992 | R - Review Commission | |
2. | 01002 | Serious | 19150052 A02 | 12/23/1991 | 12/27/1991 | $880 | $1,125 | $0 | 01/15/1992 | R - Review Commission | |
3. | 01003 | Serious | 19150052 B01 | 12/23/1991 | 12/27/1991 | $880 | $1,125 | $0 | 01/15/1992 | R - Review Commission | |
4. | 01004 | Serious | 19150052 B03 | 12/23/1991 | 01/27/1992 | $880 | $1,125 | $0 | 01/15/1992 | R - Review Commission | |
5. | 02001 | Serious | 19150052 B02 | 12/23/1991 | 12/27/1991 | $880 | $21,000 | $0 | 01/15/1992 | R - Review Commission | |
6. | 02002 | Willful | 19150052 B03 | 12/23/1991 | 12/27/1991 | $14,200 | $21,000 | $0 | 01/15/1992 | R - Review Commission | |
7. | 03001 | Other | 19150099 H | 12/23/1991 | 01/27/1992 | $0 | $0 | $0 | 01/15/1992 | R - Review Commission |
Investigation Summary
Employees were cutting in a compartment on a fishing vessel and left for a coffee break without stationing a fire watch at the site. Within 10 minutes, another employee saw smoke rising out of the compartment. The vessel was evacuated; there were no injuries. Because the compartment contained polyurethane insulation, it took the fire department two days to extinguish the fire.
Keywords: INSULATOR, WORK RULES, FIRE, SHIP, COMPARTMENT, CUTTING AND BURNING
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 109421412 | Occupation Not Listed |