Inspection Detail
Inspection: 109339853 - Jbl General Builders
Inspection Information - Office: San Francisco Ro
Site Address:
Jbl General Builders
Bachelor Housing # 16
Santa Rita, GU 96915
Mailing Address:
110 Calamendo Loop Liguan Terrace, Dededo, GU 96929
Union Status: NonUnion
SIC:1522
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 06/13/1997
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 10/14/1997
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360399315 |
Investigation Summary
Employee died of Asphyxia after inhailing paint fume.
Keywords: ASPHYXIATED, PULMONARY EDEMA, CONSTRUCTION, INHALATION, PAINT, ETHANOL, TOXIC FUMES
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 109339853 | Fatality | Asphyxia | Expediters |