Inspection: 109202010 - Betty T. Williams Food Service, Inc

Inspection Information - Office: Tampa Area Office

 

Inspection Nr: 109202010
Report ID: 0420600
Date Opened: 09/27/1995

Site Address:
Betty T. Williams Food Service, Inc
1825 N. Mills Ave.
Orlando, FL 32803

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:5812

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/27/1995

Emphasis:

Case Closed: 01/09/1997


Related Activity
Type Activity Nr Safety Health
Accident 361980881
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 4
Current Violations 4 4
Initial Penalty $3,325 $0 $0 $0 $0 $3,325
Current Penalty $2,125 $0 $0 $0 $0 $2,125
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100303 F 11/02/1995 12/05/1995 $575 $875 $0 I - Informal Settlement  
2. 01002 Serious 19100306 J02 I 11/02/1995 12/05/1995 $575 $875 $0 I - Informal Settlement  
3. 01003 Serious 19100334 A02 I 11/02/1995 11/08/1995 $575 $875 $0 I - Informal Settlement  
4. 01004A Serious 19101200 E01 11/02/1995 12/05/1995 $400 $700 $0 I - Informal Settlement  
5. 01004B Serious 19101200 G08 11/02/1995 12/05/1995 $0 $0 $0 I - Informal Settlement  
6. 01004C Serious 19101200 H 11/02/1995 12/05/1995 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 14335947
Event: 09/26/1995
ELECTRIC SHOCK - GROUND FAULT IN ELECTRIC PUMP

An employee was draining a swimming pool so that the bottom of the pool could be repainted. While he was using the pool pump, the main drain became clogged with debris. The employee found an old sewage pump that had a three-conductor cord but no plug. He had a section of two-conductor cord with a two-prong, non-polarized attachment plug and spliced it onto the pump's power supply cord. He connected the black conductor to the black conductor and the white conductor to the white conductor in both cords. He also connected the green conductor from the pump to the white conductors from both cords. He then put the pump into the pool and connected it to an extension cord set that was missing the ground prong from its attachment plug. The resulting connection reversed the plug's polarity, thus energizing the frame of the pump. He apparently touched the pump and was electrocuted.

Keywords: E GI V, ELECTRICAL, ELECTROCUTED, ATTACHMENT PLUG, GROUND FAULT, POOL, EQUIPMENT GROUNDING, ELECTRIC CORD, UNTRAINED, WATER

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 109202010 Fatality Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.