Powered by GoogleTranslate

Inspection Detail

Inspection: 109199612 - Champion

Inspection Information - Office: Birmingham Area Office

 

Inspection Nr: 109199612
Report ID: 0418300
Date Opened: 02/26/1997

Site Address:
Champion
County Road # 150
Courtland, AL 35618

Mailing Address:
P.O. Box 189, Copurtland, AL 35618

Union Status: Union

SIC:2621

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 02/26/1997

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 02/26/1997


Related Activity
Type Activity Nr Safety Health
Accident 360823249

Investigation Summary

Investigation Nr: 201270311
Event: 02/22/1997
Employees burned by green liquid from recovery boiler

Employees #1 and three coworkers sustained burns when green liquid bubbled up through the down flow pipe from the recovery boiler as it discharged into the green liquid tank.

Keywords: BURN, BOILER, STORAGE TANK, TANK, HIGH TEMPERATURE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 109199612 Occupation Not Listed
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.