Powered by GoogleTranslate

Inspection Detail

Inspection: 109176222 - Kaman Fuzing Inc

Inspection Information - Office: Bridgeport Area Office

 

Inspection Nr: 109176222
Report ID: 0111500
Date Opened: 07/26/2005

Site Address:
Kaman Fuzing Inc
217 Smith Street
Middletown, CT 06457

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3679

NAICS: 335999/All Other Miscellaneous Electrical Equipment and Component Manufacturing


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/23/2005

Emphasis:

Case Closed: 10/03/2005


Related Activity
Type Activity Nr Safety Health
Referral 202623559 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $2,250 $0 $0 $0 $0 $2,250
Current Penalty $1,250 $0 $0 $0 $0 $1,250
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100212 A01 09/01/2005 10/04/2005 $1,250 $2,250 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 201522455
Event: 07/26/2005
Employee Fractures Hand During Qualification Test

At 12:35 p.m. on July 26, 2005, Employee #1 was setting up to perform a qualification test for PCM CIA (personal computer memory card) referred to as a "shock profile" in the Environmental Test Area on the Avco shock machine, Number 250E1 3102035, Avco Corporation Humphrey Products. Employees #1 was performing set up at 1,500g and 0.5 msec, using an accelerometer, vibe system and set up on a spectroal, then he turned the Avco shock machine key in the 'on' mode, and the auto/manual switch to 'manual'. The table rose, and Employee #1 went to switch the spectroal switch (referred to as puma) across the room. He hit the arm of the puma switch and was ready to take a picture of the stock, so the table would drop and he had the level needed. This was accomplished one time with approximately 25 psi of pressure. Two switches on the back caused the table to go down at a faster rate. The process was repeated, placed the machine in the manual mode, the table rose, key switch was off, placed the block of wood underneath the table, and placed the orange pad under the table. Employee #1 then turned the key switch on, and the table dropped while in the manual mode, then to the puma switch again. The third time for set up, Employee #1 had 1,500g's, dialed in at 0.2 msec, and needed to increase the duration and install more pads. Employee #1 placed the key in the 'on' mode, 'manual' mode, the table rose up, and he shut the key switch off and placed the wood board underneath the table. The board was moved out of the way to place the orange pad under the table. While placing an orange pad under the table the board popped out, and the table dropped on his right hand, fracturing it. He was hospitalized for his injury.

Keywords: FRACTURE, FINGER, TEST EQUIPMENT, CRUSHED, STRUCK BY, HAND

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 109176222 Hospitalized injury Fracture Industrial engineers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.