Inspection Detail
Inspection: 109076323 - Georgia Power Company
Inspection Information - Office: Atlanta West Area Office
Site Address:
Georgia Power Company
Intersection Of Old Tenn. Hwy & Whitecastville
Cartersville, GA 30120
Mailing Address:
P.O. Box 4545, Atlanta, GA 30302
Union Status: Union
SIC:4911
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 10/08/1993
Emphasis:
Case Closed: 06/28/1994
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360825343 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $4,500 | $0 | $0 | $0 | $0 | $4,500 |
Current Penalty | $4,500 | $0 | $0 | $0 | $0 | $4,500 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19260021 B02 | 11/29/1993 | 01/18/1994 | $4,500 | $4,500 | $0 | 12/23/1993 | F - Formal Settlement |
Investigation Summary
An employee was installing bird wire on a utility pole. Working 24 feet above the ground, he had his pole strap around the pole and hooked into the D-rings on his body belt. A snaphook on his lanyard disengaged itself from the D-ring, and the employee fell from the pole. He died of injuries he sustained in the fall.
Keywords: SNAPHOOK ROLLOUT, POWER LINE WORKER, ELEC UTILITY WORK, FALL, FALL PROTECTION, UTILITY POLE
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 109076323 | Fatality | Other | Electrical power installers and repairers |