Powered by GoogleTranslate

Inspection Detail

Inspection: 109040931 - Ebr Manufacturing, Inc.

Inspection Information - Office: Hasbrouck Heights Area Office

 

Inspection Nr: 109040931
Report ID: 0214500
Date Opened: 03/16/1993

Site Address:
Ebr Manufacturing, Inc.
50 Railroad Avenue
Closter, NJ 07624

Mailing Address:
P.O. Box 374, Closter, NJ 07624

Union Status: Union

SIC:3083

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 03/23/1993

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 11/12/1993


Related Activity
Type Activity Nr Safety Health
Accident 360660369
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 1 1
Initial Penalty $2,600 $0 $0 $0 $0 $2,600
Current Penalty $600 $0 $0 $0 $0 $600
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01002 Serious 19100147 D02 04/05/1993 05/10/1993 $2,000 $2,000 $0 04/26/1993 F - Formal Settlement Citation has been deleted.
2. 01003 Serious 19100212 A01 04/05/1993 05/10/1993 $600 $600 $0 04/26/1993 F - Formal Settlement  

Investigation Summary

Investigation Nr: 14492474
Event: 03/16/1993
ELECTRIC SHOCK - DIRECT CONTACT WITH ENERGIZED PARTS

AN EMPLOYEE WAS OPERATING A PLASTIC QUILTING MACHINE. HE NOTICED A MALFUNCTION IN THE MACHINE--ELECTRICAL CONTACTS ON THE DIE WERE ARCING. THE EMPLOYEE SHUT THE MACHINE DOWN, WENT TO THE DIE AREA, AND REMOVED A BARRIER GUARD. HE THEN LEANED ABOUT 3.5 FEET INTO THE MACHINE TO EXAMINE THE CONTACTS. THE EMPLOYEE APPARENTLY APPROACHED TOO CLOSE TO THE 10-KILOVOLT, RADIO-FREQUENCY CONTACTS AND WAS ELECTROCUTED. THE GUARD WAS FOUND TO BE CAPABLE OF BEING REMOVED EASILY BY ANYONE, AND NO INTERLOCKING OF THE MECHANICAL OR ELECTRICAL COMPONENTS OF THE MACHINE WAS PROVIDED.

Keywords: E GI IV, ELECTRICAL, ELECTROCUTED, LOCKOUT, UNGUARDED LIVE PARTS, ELEC CIRC PART--MISC, UNTRAINED, ELEC EQUIPMENT--MISC

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 109040931 Fatality Electric Shock Misc. metal & plastic processing machine operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.