Powered by GoogleTranslate

Inspection Detail

Inspection: 109004523 - Quality Electric Contractor Inc.

Inspection Information - Office: Fort Lauderdale Area Office

 

Inspection Nr: 109004523
Report ID: 0418800
Date Opened: 11/25/1992

Site Address:
Quality Electric Contractor Inc.
P.O. Box 1688
Clewiston, FL 33440

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:1731

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 05/17/1993

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 04/05/1994


Related Activity
Type Activity Nr Safety Health
Accident 360955314
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $2,000 $0 $0 $0 $0 $2,000
Current Penalty $1,000 $0 $0 $0 $0 $1,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19260020 B02 05/19/1993 02/28/1994 $1,000 $2,000 $0 F - Formal Settlement  
2. 01001B Serious 19260550 A15 I 05/19/1993 06/04/1993 $0 $0 $0 06/03/1993 F - Formal Settlement  
3. 01001C Serious 19260550 A15 IV 05/19/1993 05/24/1993 $0 $0 $0 F - Formal Settlement  

Investigation Summary

Investigation Nr: 819896
Event: 11/25/1992
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU BOOM

FOUR EMPLOYEES WERE PUSHING ON A CYLINDRICAL CONCRETE BASE THAT WAS SUSPENDED BY A CRANE. THEY WERE GUIDING THE BASE INTO A HOLE IN THE GROUND. THE CRANE'S BOOM WAS WITHIN 1 FOOT OF A 23-KILOVOLT OVERHEAD POWER LINE. AS THE EMPLOYEES PUSHED ON THE BASE, THEY MOVED THE BOOM INTO THE POWER LINE. TWO EMPLOYEES WERE ELECTROCUTED, AND THREE OTHERS (TWO OF WHOM WERE HOSPITALIZED) RECEIVED ELECTRIC SHOCKS. (THE ORIGINAL ABSTRACT DID NOT STATE WHAT THE FIFTH EMPLOYEE WAS DOING AT THE TIME OF THE ACCIDENT.)

Keywords: OVERHEAD POWER LINE, ELECTRICAL, E GI IA, ELECTRIC SHOCK, BOOM, CRANE BOOM, ELECTROCUTED, CRANE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 109004523 Hospitalized injury Electric Shock Occupation not reported
2 109004523 Non Hospitalized injury Electric Shock Occupation not reported
3 109004523 Hospitalized injury Electric Shock Occupation not reported
4 109004523 Fatality Electric Shock Occupation not reported
5 109004523 Fatality Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.