Powered by GoogleTranslate

Inspection Detail

Inspection: 1089663 - R N H Corporation

Inspection Information - Office: Syracuse Area Office

 

Inspection Nr: 1089663
Report ID: 0215800
Date Opened: 06/15/1984

Site Address:
R N H Corporation
Rd 4 Harp Rd
Canastota, NY 13032

Mailing Address:
Po Box 284-A Harp Road, Canastota, NY 13032

Union Status: NonUnion

SIC:3089

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 07/13/1984

Planning Guide: Health-Manufacturing

Emphasis:

Case Closed: 08/15/1984


Related Activity
Type Activity Nr Safety Health
Accident 360572218
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $200 $0 $0 $0 $0 $200
Current Penalty $100 $0 $0 $0 $0 $100
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19101000 A01 07/24/1984 08/09/1984 $100 $200 $0 I - Informal Settlement  
2. 01001B Serious 19101000 E 07/24/1984 08/09/1984 $0 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 14489678
Event: 06/15/1984
Seven injured after inhaling hydrochloric acid

Employees #1 through #7 were preparing a plastic molding machine that had been running polyvinyl chloride (PVC) at 350 degrees F to run nylon at 500 degrees F. During the changeover, the purging step to remove PVC remaining in the molding machine was inadvertently left out. When the hot nylon hit the PVC in the machine, hydrochloric acid was formed through the thermal decomposition of PVC. The hydrochloric acid escaped into the workplace, exposing Employees #1 through #7 to a level that exceeded its ceiling limit. The employees suffered injuries to their eyes, throats, and lungs and were hospitalized. Employees #1 through #7 were not equipped with ppe.

Keywords: THROAT, HYDROCHLORIC ACID, LUNG, INADEQUATE MAINT, PPE, MOLDING MACHINE, WORK RULES, INHALATION, CHEMICAL REACTION, POLYVINYL CHLORIDE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1089663 Hospitalized injury Other Electrical and electronic engineers
2 1089663 Hospitalized injury Other Electrical and electronic engineers
3 1089663 Hospitalized injury Other Electrical and electronic engineers
4 1089663 Hospitalized injury Other Electrical and electronic engineers
5 1089663 Hospitalized injury Other Electrical and electronic engineers
6 1089663 Hospitalized injury Other Electrical and electronic engineers
7 1089663 Hospitalized injury Other Electrical and electronic engineers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.