Inspection Detail
Inspection: 108871658 - Luckinbill, Inc.
Inspection Information - Office: Oklahoma City Area Office
Site Address:
Luckinbill, Inc.
304 E. Broadway
Altus, OK 73521
Mailing Address:
P. O. Box 186, Enid, OK 73702
Union Status: NonUnion
SIC:7623
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 04/19/1996
Emphasis:
Case Closed: 07/16/1996
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 361824519 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 3 | 3 | ||||
| Current Violations | 3 | 3 | ||||
| Initial Penalty | $16,800 | $0 | $0 | $0 | $0 | $16,800 |
| Current Penalty | $6,405 | $0 | $0 | $0 | $0 | $6,405 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100332 B01 | 05/30/1996 | 06/17/1996 | $2,135 | $5,600 | $0 | I - Informal Settlement | ||
| 2. | 01002 | Serious | 19100333 A02 | 05/30/1996 | 06/17/1996 | $2,135 | $5,600 | $0 | I - Informal Settlement | ||
| 3. | 01003 | Serious | 19100335 A01 I | 05/30/1996 | 06/17/1996 | $2,135 | $5,600 | $0 | I - Informal Settlement |
Investigation Summary
A service worker and a supervisor for an air conditioning repair shop were performing a routine preseason preventive maintenance check on a rooftop condenser unit for an air conditioner. With the control cabinet cover removed, the service worker began taking current measurements. The top of this condensing unit (as the other similar units) stood about 0.6 meters (2 feet) above the tar-and-gravel-covered roof. To place the ammeter over the appropriate conductor with the air conditioner in operation, the employee had to maneuver his hands and arms around a 240-volt contact on a motor relay and two capacitors. He was in an unstable kneeling position and lost his balance, falling into the open cabinet. His right arm contacted the motor relay while his left arm was touching the grounded case of the unit. The employee was electrocuted.
Keywords: E GI II, ELEC PROTECT EQUIP, MAINTENANCE, ELECTRICAL, AIR CONDITIONER, ELECTROCUTED, ELEC CIRC PART--MISC, ELECTRICAL CABINET
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 108871658 | Fatality | Electric Shock | Heating, air conditioning, and refrig. mechanics |
Translate