Inspection: 108866237 - Ward Drilling Company, Inc.

Inspection Information - Office: Oklahoma City Area Office

 

Inspection Nr: 108866237
Report ID: 0627700
Date Opened: 07/24/1995

Site Address:
Ward Drilling Company, Inc.
Junction Hwy 44 & 55
Sentinel, OK 73664

Mailing Address:
P. O. Box 3370, Enid, OK 73702

Union Status: NonUnion

SIC:1381

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/24/1995

Emphasis:

Case Closed: 10/02/1995


Related Activity
Type Activity Nr Safety Health
Accident 361121544
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 1 3
Current Violations 2 1 3
Initial Penalty $6,375 $0 $0 $0 $0 $6,375
Current Penalty $6,375 $0 $0 $0 $0 $6,375
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19100303 C 08/31/1995 09/13/1995 $5,000 $5,000 $0 -  
2. 01001B Serious 19100304 E01 I 08/31/1995 09/13/1995 $0 $0 $0 -  
3. 01001C Serious 19100305 G02 II 08/31/1995 09/13/1995 $0 $0 $0 -  
4. 01002 Serious 19101030 C01 I 08/31/1995 10/03/1995 $1,375 $1,375 $0 -  
5. 02001 Other 19100334 A02 I 08/31/1995 09/18/1995 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 771600
Event: 07/23/1995
ELECTRIC SHOCK - GROUND FAULT IN ELECTRIC PUMP

A four-person crew was working the daylight shift on a drilling rig. They were drilling a gas well. Three of the employees were directed to set up an electric pump to recirculate excess water from the haul-off pits to the mud pits. The 480-volt, 80-ampere, three-phase pump was initially set on the east haul-off pit. It did not work properly. It was then placed on a wooden pallet on the ground. Apparently, as one of the employees turned the pump on, a ground fault occurred. This energized the frame of the pump, and the employee was electrocuted. A splice in the power supply cord had failed, causing a phase-to-phase fault, which subsequently resulted in a phase-to-ground fault.

Keywords: E GI III, ELECTRICAL, ELECTROCUTED, ELECTRIC PUMP, GROUND FAULT, EQUIPMENT GROUNDING

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 108866237 Fatality Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.