Powered by GoogleTranslate

Inspection Detail

Inspection: 108771031 - Zapco Energy Tactics Corp

Inspection Information - Office: Concord Area Office

 

Inspection Nr: 108771031
Report ID: 0111700
Date Opened: 01/09/1996

Site Address:
Zapco Energy Tactics Corp
625 Dunbarton Road, Manchester Landfill
Manchester, NH 01013

Mailing Address:
124 Sills Road, Yaphank, NY 11890

Union Status: NonUnion

SIC:4911

NAICS: 0 


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 06/14/1996

Emphasis:

Case Closed: 04/20/1999


Related Activity
Type Activity Nr Safety Health
Referral 901667527 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 5 2 7
Current Violations 5 1 1 7
Initial Penalty $27,900 $126,000 $0 $0 $0 $153,900
Current Penalty $7,000 $26,500 $0 $0 $26,500 $60,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100037 F02 07/02/1996 07/08/1996 $1,250 $4,500 $0 07/22/1996 F - Formal Settlement  
2. 01002 Serious 19100269 D02 III 07/02/1996 08/06/1996 $1,500 $6,300 $0 07/22/1996 F - Formal Settlement  
3. 01003 Serious 19100269 D02 VI 07/02/1996 08/06/1996 $1,500 $6,300 $0 07/22/1996 F - Formal Settlement  
4. 01004 Serious 19100269 D03 I 07/02/1996 08/06/1996 $1,500 $6,300 $0 07/22/1996 F - Formal Settlement  
5. 01005 Serious 19100332 B01 07/02/1996 08/06/1996 $1,250 $4,500 $0 07/22/1996 F - Formal Settlement  
6. 02001 Unclass 5A0001 07/02/1996 07/08/1996 $26,500 $63,000 $0 07/22/1996 F - Formal Settlement  
7. 02002 Willful 19100307 B 07/02/1996 07/08/1996 $26,500 $63,000 $0 07/22/1996 F - Formal Settlement  

Investigation Summary

Investigation Nr: 14529150
Event: 01/03/1996
METHANE FIRE/EXPLOSION

Two electric utility employees were working in a landfill gas compressor shed. The shed was 7.3 meters long, 6.4 meters wide, and 2.7 meters high. The relief valves for the methane gas installation vented inside the shed. Ordinary (non-explosion proof) electric equipment had been installed in the shed. A negative pressure ventilation system had been installed; however, it was compromised because the louvers were nailed shut. One of the two employees went into the shed to check a control panel, and then the second employee opened one of the two doors to enter the shed. Apparently, there was an ignitable concentration of methane in the shed, and the gas ignited. (The source of ignition was not identified.) Both employees later reported smelling a heavy gas odor just before ignition. The explosion severely burned the two employees, and they were hospitalized for their injuries. One was released soon after the accident, but the other was hospitalized for several days. The more severely injured employee remained out of work for an extra period of time because he also injured his shoulder when he tried to ram down the shed door to escape the burning building. (The doors opened inwards.) 0620

Keywords: BURN, SAFETY RELIEF VALVE, VENTING, FIRE, NATURAL GAS, EXPLOSION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 108771031 Hospitalized injury Burn/Scald(Heat) Occupation not reported
2 108771031 Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close