Inspection Detail
Inspection: 108719477 - Sebright Induction Metal Treating Co.
Inspection Information - Office: Chicago South Area Office
Site Address:
Sebright Induction Metal Treating Co.
3252 West 31st Street
Chicago, IL 60623
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3471
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 10/15/1993
Emphasis:
Case Closed: 11/18/1993
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360966089 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 19100147 C01 | 10/19/1993 | 12/29/1993 | $0 | $0 | $0 | - |
Investigation Summary
An employee was performing the final check of a Linberg Hi-Frequency induction generator (Tag. No. 1-175; Contract No. DARE-11-67-C-0289(T)) after the installation of three new capacitors. The three 0.0054-microfarad, water-cooled capacitors (General Electric Model No. 1290; Catalog No. 19F2411) were rated at 9000 volts and 165 amperes, rms. The employee noticed water leaking from one of the hoses that connect to the capacitors. He then opened the door to the unit, which was interlocked to deenergize the generator. However, he did not ground the circuit to discharge the capacitors. When he stepped into the generator, he apparently contacted a circuit part that was still energized through the residual charge on the capacitors and was electrocuted.
Keywords: PROTECTIVE GROUNDING, E GI IV, ELECTRICAL, ELECTROCUTED, CAPACITOR, LOCKOUT, ELEC CIRC PART--MISC
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 108719477 | Fatality | Electric Shock | Occupation not reported |
Translate