Inspection Detail
Inspection: 108646274 - Barth Electrical Company Inc
Inspection Information - Office: Indiana Department Of Labor
Site Address:
Barth Electrical Company Inc
(Lilly Corporate Center) 301 E Mccarty
Indianapolis, IN 46225
Mailing Address:
Attn Elmer Van Deman 1934 N Illinois, Indianapolis, IN 46202
Union Status: Union
SIC:1731
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 09/21/1990
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 03/11/1991
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360469258 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $180 | $0 | $0 | $0 | $0 | $180 |
Current Penalty | $180 | $0 | $0 | $0 | $0 | $180 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19260556 B02 VII | 10/11/1990 | 10/14/1990 | $180 | $180 | $0 | - |
Investigation Summary
At approximately 9:00 a.m. on September 10, 1990, Employees #1 and #2 were working on a Marklift Rt 25 gas-powered scissor lift scaffold installing 5 in. by 10 ft. rigid conduit pipe at a height of approximately 15 ft. The scissor lift was on a concrete floor with a 5 degree incline when it unexpectedly started rolling (the lift engine was not running) down the incline. Employee #2 started the engine in order to stop the lift from rolling and the lift stopped abruptly. Employee #2 suffered neck and shoulder injuries and Employee #1 suffered hamstring injuries and bruises.
Keywords: INSTALLING, SHOULDER, UNSECURED, WORK RULES, CONSTRUCTION, NECK, SLOPE, AERIAL LIFT, CONTUSION, LEG
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 108646274 | Non Hospitalized injury | Bruise/Contus/Abras | Electricians | ||
2 | 108646274 | Non Hospitalized injury | Strain/Sprain | Electricians |