Powered by GoogleTranslate

Inspection Detail

Inspection: 108559063 - Faultless Caster Division

Inspection Information - Office: Indiana Department Of Labor

 

Inspection Nr: 108559063
Report ID: 0551800
Date Opened: 09/05/1990

Site Address:
Faultless Caster Division
1421 North Garvin Street
Evansville, IN 47711

Mailing Address:
, , 00000

Union Status: Union

SIC:3429

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/02/1990

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 01/25/1991


Related Activity
Type Activity Nr Safety Health
Accident 361039480
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 4
Current Violations 4 4
Initial Penalty $3,060 $0 $0 $0 $0 $3,060
Current Penalty $2,500 $0 $0 $0 $0 $2,500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100147 C01 12/27/1990 02/15/1991 $540 $720 $0 I - Informal Settlement  
2. 01002A Serious 19100217 B07 VIII 12/27/1990 02/15/1991 $810 $810 $0 -  
3. 01002B Serious 19100217 C02 IA 12/27/1990 02/15/1991 $0 $0 $0 -  
4. 01004 Serious 19100217 D01 II 12/27/1990 01/08/1991 $610 $810 $0 I - Informal Settlement  
5. 01005 Serious 19100217 F02 12/27/1990 02/15/1991 $540 $720 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 903658
Event: 07/19/1990
Employee's thumb amputated by cycling power press

At 2:30 p.m. on July 19, 1990, Employee #1 was operating a part-revolution mechanical power press on continuous cycle. When Employee #1 pushed the cycle-interrupt button and reached into the die area to remove bent parts, the press cycled and cut off her right thumb between the knuckle and the hand. Employee #1 was transported to Deaconess Hospital, Evansville, IN, then transported to Jewish Hospital, Louisville, KY, where the thumb was surgically reattached.

Keywords: AMPUTATED, POWER PRESS, WORK RULES, THUMB, POINT OF OPERATION, MECH MALFUNCTION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 108559063 Hospitalized injury Amputation Punching and stamping press machine operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close