Inspection Detail
Inspection: 1084876.015 - Callaway Outdoor Designs
Inspection Information - Office: Houston North Area Office
Site Address:
Callaway Outdoor Designs
610 Thistlewood Drive
Houston, TX 77079
Mailing Address:
3923 Emerald Lake Dr., Missouri City, TX 77459
Union Status: NonUnion
SIC:
NAICS: 561730/Landscaping Services
Inspection Type: Fat/Cat
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 08/13/2015
Emphasis:
Case Closed: 02/22/2016
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 1010304 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | 2 | |||
| Current Violations | 1 | 1 | 2 | |||
| Initial Penalty | $7,000 | $0 | $0 | $2,000 | $0 | $9,000 |
| Current Penalty | $4,900 | $0 | $0 | $1,400 | $0 | $6,300 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 5A0001 | 12/14/2015 | 02/19/2016 | $4,900 | $7,000 | $0 | I - Informal Settlement | ||
| 2. | 02001 | Other | 19040039 A01 | 12/14/2015 | 02/19/2016 | $1,400 | $2,000 | $0 | I - Informal Settlement |
Investigation Summary
At 6:30 p.m. on August 7, 2015, an employee was repairing a small break in a sprinkler line. When the employee found a PVC pipe that he thought was the damaged pipe, he cut through it with a hand held cutter. The pipe that the employee cut turned out to be an electrical conduit containing what was believed to be a 110-volt wire supplying power to an outside light. The Employee was electrocuted.
Keywords: Electrical, Electrocuted, Wire Line
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1084876.015 | 33 | M | Fatality | Laborers, except construction |
Translate