Powered by GoogleTranslate

Inspection Detail

Inspection: 108408808 - English American Tailoring

Inspection Information - Office: Department Of Labor, Licensing, And Regulation Division Of Labor And Industry Maryland Occupational Safety And Health

 

Inspection Nr: 108408808
Report ID: 0352420
Date Opened: 09/15/1989

Site Address:
English American Tailoring
411 North Cranberry Rd
Westminster, MD 21157

Mailing Address:
P.O. Box 585, Westminster, MD 21157

Union Status: Union

SIC:2311

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/30/1989

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 12/18/1989


Related Activity
Type Activity Nr Safety Health
Accident 360622005
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 6 1 7
Current Violations 6 1 7
Initial Penalty $3,875 $0 $1,690 $0 $0 $5,565
Current Penalty $3,875 $0 $1,690 $0 $0 $5,565
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Repeat 19100133 A 1 11/22/1989 11/25/1989 $1,690 $1,690 $0 -  
2. 02001 Serious 890032 A 11/22/1989 11/25/1989 $680 $680 $0 -  
3. 03001 Serious 19100132 A 11/20/1989 11/23/1989 $710 $710 $0 -  
4. 04001 Serious 19100157 G 1 11/22/1989 11/25/1989 $605 $605 $0 -  
5. 05001 Serious 19100212 A 1 11/22/1989 11/25/1989 $670 $670 $0 -  
6. 06001 Serious 19100303 B 2 11/22/1989 11/25/1989 $605 $605 $0 -  
7. 07001 Serious 19100303 G 2 I 11/22/1989 11/25/1989 $605 $605 $0 -  

Investigation Summary

Investigation Nr: 741579
Event: 09/14/1989
ELECTRIC SHOCK - DIRECT CONTACT WITH ENERGIZED PARTS

A MECHANIC WHO WAS IN CHARGE OF SERVICING LASER CUTTING SYSTEMS WAS ADJUSTING THE INTENSITY OF A LASER. THE LASER WAS PART OF AN ACME/CLEVELAND LASER CUTTING SYSTEM (MODEL NO. L510-S). THE EMPLOYEE, WHO HAD RECEIVED ON-THE-JOB TRAINING, GAINED ACCESS TO THE LASER'S LENS BY REMOVING AN ELECTRICAL PANEL ON THE SIDE OF THE LASER. WITH THE LASER ENERGIZED AT 20 KILOVOLTS D-C, THE MECHANIC REACHED INSIDE AND ADJUSTED THE LENS ON THE LASER WITH AN INSULATING TOOL. HE WAS KNEELING ON THE CONCRETE FLOOR NEXT TO THE LASER AND WAS NOT WEARING RUBBER INSULATING GLOVES. AS HE WAS DOING THIS, THE BACK OF HIS LEFT HAND CONTACTED THE END OF THE LASER, AND HE RECEIVED AN ELECTRIC SHOCK. THE EMPLOYEE WAS HOSPITALIZED FOR HIS INJURY.

Keywords: E GI II, ELEC PROTECT EQUIP, ELECTRICAL, LASER, ELEC CIRC PART--MISC, ELECTRIC SHOCK, ELEC EQUIPMENT--MISC

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 108408808 Hospitalized injury Electric Shock Supervisors, mechanics and repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.