Inspection Detail
Inspection: 108270109 - Permapost Products Co
Inspection Information - Office: Or-E-Portland - Safety 1 1054111
Site Address:
Permapost Products Co
25600 Sw Tualatin Valley Hwy
Hillsboro, OR 97123
Mailing Address:
Po Box 100, Hillsboro, OR 97123
Union Status: NonUnion
SIC:2491
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 11/05/1990
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 03/06/1991
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360628465 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 2 | ||||
| Current Violations | 2 | 2 | ||||
| Initial Penalty | $3,000 | $0 | $0 | $0 | $0 | $3,000 |
| Current Penalty | $2,500 | $0 | $0 | $0 | $0 | $2,500 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001A | Serious | 767028502 | 12/26/1990 | 12/29/1990 | $2,500 | $2,500 | $0 | 01/08/1991 | - | |
| 2. | 01001B | Serious | 740006502 | 12/26/1990 | 12/29/1990 | $0 | $0 | $0 | 01/08/1991 | - | |
| 3. | 01001C | Serious | 740006501 | 12/26/1990 | 12/29/1990 | $0 | $0 | $0 | 01/08/1991 | - | |
| 4. | 01002 | Serious | 767031001 C | 12/26/1990 | 12/29/1990 | $0 | $500 | $0 | 01/08/1991 | L - State Settlement |
Investigation Summary
An employee was discovered behind a radial arm saw near the west wall of a fabrication shop. He had been electrocuted. His son had last seen him 24 hours earlier. At the time, they were working together to do some after-hours contract work, consisting of building curb stops out of 250-millimeter-diameter logs. It appears that the employee had climbed over the roll case and had gone behind the radial arm saw. There were no witnesses to the accident, and all power sources were deenergized after the accident, so the exact cause of the accident could not be determined. However, a 480-volt extension cord set was found lying under and on the employee's body. Additionally, the area contained an electrical box on the back of the radial arm saw. The back side of the box was missing, exposing circuit parts energized at 480 volts.
Keywords: E GI V, ELECTRICAL, ELECTROCUTED, ELECTRIC SAW, GROUND FAULT, ELECTRIC CORD, ELECTRICAL BOX
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 108270109 | Fatality | Electric Shock | Miscellaneous woodworking machine operators |