Powered by GoogleTranslate

Inspection Detail

Inspection: 108183203 - I-10 International Trucks Inc

Inspection Information - Office: Arizona Division Of Occupational Safety And Health (Adosh)

 

Inspection Nr: 108183203
Report ID: 0950411
Date Opened: 07/13/1990

Site Address:
I-10 International Trucks Inc
2202 S Central Ave
Phoenix, AZ 85003

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:7699

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 07/20/1990

Planning Guide: Health-Manufacturing

Emphasis:

Case Closed: 09/04/1990


Related Activity
Type Activity Nr Safety Health
Accident 360185250
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 5 5
Current Violations 5 5
Initial Penalty $0 $0 $0 $0 $0 $0
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 19100215 A04 08/24/1990 08/27/1990 $0 $0 $0 -  
2. 01002 Other 19100215 B09 08/24/1990 08/27/1990 $0 $0 $0 -  
3. 01003 Other 19100305 G02 II 08/24/1990 08/27/1990 $0 $0 $0 -  
4. 01004 Other 19101200 E01 08/24/1990 09/23/1990 $0 $0 $0 -  
5. 01005 Other 19101200 G01 08/24/1990 09/23/1990 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 170065635
Event: 07/13/1990
Employee killed by chemical gases in confined space

At approximately 8:10 p.m. on July 12, 1990, Employee #1 was working on an air conditioning unit in a confined space that measured 39 in. by 16 in. by 48 in. He had taken with him Sercon aerosol flush, which contained trichlorofluoromethane and dichlorodifluoromethane (freon), and Solder Seal brake cleaner gunk, containing methyl chloroform and perchloroethylene, with carbon dioxide as a propellant. He was found with his face down, and his head, shoulders, and arms inside an opening measuring 10 1/2 in. high by 17 in. wide. He was blue and had no pulse. Employee #1 never regained consciousness and was pronounced dead by the medical examiner at 9:01 p.m. at Phoenix Memorial Hospital. The cause of death was inhalation of methyl chloroform and perchloroethylene.

Keywords: UNCONSCIOUSNESS, CONFINED SPACE, PPE, AIR CONDITIONER, WORK RULES, INHALATION, METHYL CHLOROFORM, PERCHLOROETHYLENE, CHEMICAL VAPOR, TOXIC FUMES

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 108183203 Fatality Asphyxia Bus, truck and stationary engine mechanics
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close