Powered by GoogleTranslate

Inspection Detail

Inspection: 108118787 - Basic Drilling Co.

Inspection Information - Office: Arizona Division Of Occupational Safety And Health (Adosh)

 

Inspection Nr: 108118787
Report ID: 0950411
Date Opened: 03/06/1991

Site Address:
Basic Drilling Co.
1408 W Apache Trial
Apache Junction, AZ 85220

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:1629

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 03/26/1991

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 08/20/1991


Related Activity
Type Activity Nr Safety Health
Accident 360184535
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 3 4
Current Violations 1 3 4
Initial Penalty $700 $0 $0 $0 $0 $700
Current Penalty $575 $0 $0 $0 $0 $575
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 230403 A 05/31/1991 06/03/1991 $575 $700 $0 I - Informal Settlement  
2. 02001 Other 19260059 E01 05/31/1991 06/30/1991 $0 $0 $0 -  
3. 02002 Other 19260059 G08 05/31/1991 06/30/1991 $0 $0 $0 -  
4. 02003 Other 19260059 H 05/31/1991 06/30/1991 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 170064679
Event: 03/04/1991
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU BOOM

Two employees were drilling a pit. One of them was attaching a red flag to the rear of the drilling truck, as the other employee was lowering the boom on the rig. The boom contacted a 7200-volt overhead power line. The employee at the rear of the truck received an electric shock and was knocked unconscious. The other employee got off the drilling rig, called for help, and administered cardio-pulmonary resuscitation to his injured coworker. Emergency medical services treated the injured employee, who was air lifted to a hospital. He was discharged from the hospital 3 days after the accident.

Keywords: UNCONSCIOUSNESS, OVERHEAD POWER LINE, ELECTRICAL, BOOM, CPR, E GI IA, DRILL RIG--NON-OIL, ELECTRIC SHOCK

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 108118787 Hospitalized injury Electric Shock Excavating and loading machine operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.