Inspection Detail
Inspection: 108117029 - Pueblo Heights Mobile Home Park
Inspection Information - Office: Arizona Division Of Occupational Safety And Health (Adosh)
Site Address:
Pueblo Heights Mobile Home Park
1630 Six Shooter Canyon
Globe, AZ 85501
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:6515
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 10/30/1990
Emphasis: L:Fall
Case Closed: 01/22/1991
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360188148 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $1,400 | $0 | $0 | $0 | $0 | $1,400 |
| Current Penalty | $1,400 | $0 | $0 | $0 | $0 | $1,400 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100132 A | 12/11/1990 | 12/14/1990 | $1,400 | $1,400 | $0 | - |
Investigation Summary
Employee #1 was last seen alive at approximately 8:30 a.m. on June 5, 1990. At approximately 5:15 p.m. he was found dead in a sewage disposal tank. There are some unanswered questions about his death and the cause of death is unknown.
Keywords: FALL, SEWAGE, TANK
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 108117029 | Fatality | Asphyxia | Water and sewage treatment plant operators |