Powered by GoogleTranslate

Inspection Detail

Inspection: 108005737 - Developmental Services Inc

Inspection Information - Office: Indiana Department Of Labor

 

Inspection Nr: 108005737
Report ID: 0551800
Date Opened: 10/11/1989

Site Address:
Developmental Services Inc
Highway 421, Po Box 489
Greensburg, IN 47240

Mailing Address:
2920 10th St, Columbus, IN 47202

Union Status: NonUnion

SIC:7389

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/01/1989

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 12/18/1989


Related Activity
Type Activity Nr Safety Health
Accident 360196455
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 1 3
Current Violations 2 1 3
Initial Penalty $480 $0 $0 $0 $0 $480
Current Penalty $480 $0 $0 $0 $0 $480
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19100217 A01 I 11/27/1989 01/01/1990 $240 $240 $0 -  
2. 01001B Serious 19100217 B06 I 11/27/1989 01/02/1990 $0 $0 $0 -  
3. 02001 Other 19100305 A01 I 11/27/1989 01/02/1990 $0 $0 $0 -  
4. 10001A Serious 19100217 A01 I 11/27/1989 01/02/1990 $240 $240 $0 -  

Investigation Summary

Investigation Nr: 904854
Event: 08/18/1989
EMPLOYEE INJURED IN POWER PRESS CLUTCH MALFUNCTION

At approximately 10:15 a.m. On August 18, 1989, Employee #1 initiated the first-trip cycle leakage on a press because it failed to trip the previous week. Maintenance help was brought in from one of the company's outside contracting companies to perform maintenance on the press. The next morning on the first cycle, Employee #1 initiated his press directly into continuous mode. Employee #1 began moving the die slide forward toward him while sitting on a stool. The repeated motion of the lap of the operator caused the die slide to blast right through two safety stops and lacerates Employee #1's penis. Employee #1 was treated and sent back to work within an hour. Teflon tape had been placed in the exhaust part on the clutch control valve, overriding all electrical systems and the single-stroke mechanism the press.

Keywords: MAINTENANCE, DIE CUTTING PRESS, PENIS, LACERATION, PRESS

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 108005737 Non Hospitalized injury Burn(Chemical) Punching and stamping press machine operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.