Powered by GoogleTranslate

Inspection Detail

Inspection: 108005505 - The Dallas Group Of America, Inc.

Inspection Information - Office: Indiana Department Of Labor

 

Inspection Nr: 108005505
Report ID: 0551800
Date Opened: 07/24/1989

Site Address:
The Dallas Group Of America, Inc.
1402 Fabricon Blvd
Jeffersonville, IN 47130

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:2834

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/24/1989

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 08/29/1989


Related Activity
Type Activity Nr Safety Health
Accident 360471296

Investigation Summary

Investigation Nr: 975607
Event: 07/15/1989
EMPLOYEE KILLED BY NITROUS OXIDE ASPHYXIATION.

At about 2:50 p.m., Employee #1 who was working as a temporary quality control technician for Dallas Group of America Incorporated placed a dual-cartridge light gas and organic vapor respirator over her face. She then took a 6 ft-long clear flexible vinyl tube, connected it to a cylinder of nitrous oxide gas, and opened the valve on the cylinder. Placing the tube deep into her mouth, she laid down on the floor next to the cylinder, and was killed as a result asphyxiation.

Keywords: ASPHYXIATED, SUICIDE, NITROUS OXIDE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 108005505 Fatality Asphyxia Furnace, kiln and oven operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close