Powered by GoogleTranslate

Inspection Detail

Inspection: 107980435 - Frank E Irish Inc

Inspection Information - Office: Indiana Department Of Labor

 

Inspection Nr: 107980435
Report ID: 0551800
Date Opened: 12/05/1989

Site Address:
Frank E Irish Inc
(Boehringer-Mannheim) 9115 N Hague Rd
Indianapolis, IN 46256

Mailing Address:
9115 N Hague Rd, Indianapolis, IN 46256

Union Status: Union

SIC:1711

NAICS: 0 


Inspection Type: Planned

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 12/12/1989

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 07/10/1990


Related Activity
Type Activity Nr Safety Health
Accident 360197008
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 2
Current Violations 1 1 2
Initial Penalty $150 $0 $0 $0 $0 $150
Current Penalty $60 $0 $0 $0 $0 $60
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260028 A 12/15/1989 12/21/1989 $60 $150 $0 01/08/1990 F - Formal Settlement  
2. 02001 Other 19260059 G01 12/15/1989 01/16/1990 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 976571
Event: 06/12/1989
HIT BY FLYING OBJECT - ELECTRICAL FAULT IN CONTROL UNIT

AN EMPLOYEE WAS SETTING UP AN ENFUSION CONTROL UNIT TO FUSE 4-INCH POLYPROPYLENE PIPE. HE MADE THE CONNECTIONS TO THE CONTROL UNIT FOR THE PIPE TO BE FUSED, AND THEN HE PLUGGED THE CONTROL UNIT INTO A 20-AMPERE, 120-VOLT RECEPTACLE OUTLET. HE WENT TO THE CONTROL UNIT TO START THE ENFUSION PROCESS AND NOTICED THAT THERE WERE NO READINGS ON THE UNIT AND THAT THE PANEL WAS NOT LIT. HE TURNED THE RESET KNOB ON THE CONTROL UNIT, AND THE UNIT BLEW APART WITH A LOUD BOOM. THE EMPLOYEE WAS STRUCK IN THE FACE AND THE EYE BY THE CONTROL PANEL. HE WAS TAKEN TO A HOSPITAL, WHERE HE WAS TREATED FOR EYE DAMAGE AND RELEASED.

Keywords: E GI III, ELECTRICAL, ELECTRICAL FAULT, FLYING OBJECT, ELEC EQUIPMENT--MISC

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 107980435 Non Hospitalized injury Bruise/Contus/Abras Plumbers, pipefitters and steamfitters
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.