Inspection Detail
Inspection: 107980435 - Frank E Irish Inc
Inspection Information - Office: Indiana Department Of Labor
Site Address:
Frank E Irish Inc
(Boehringer-Mannheim) 9115 N Hague Rd
Indianapolis, IN 46256
Mailing Address:
9115 N Hague Rd, Indianapolis, IN 46256
Union Status: Union
SIC:1711
NAICS: 0
Inspection Type: Planned
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 12/12/1989
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 07/10/1990
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360197008 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | 2 | |||
Current Violations | 1 | 1 | 2 | |||
Initial Penalty | $150 | $0 | $0 | $0 | $0 | $150 |
Current Penalty | $60 | $0 | $0 | $0 | $0 | $60 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19260028 A | 12/15/1989 | 12/21/1989 | $60 | $150 | $0 | 01/08/1990 | F - Formal Settlement | |
2. | 02001 | Other | 19260059 G01 | 12/15/1989 | 01/16/1990 | $0 | $0 | $0 | - |
Investigation Summary
AN EMPLOYEE WAS SETTING UP AN ENFUSION CONTROL UNIT TO FUSE 4-INCH POLYPROPYLENE PIPE. HE MADE THE CONNECTIONS TO THE CONTROL UNIT FOR THE PIPE TO BE FUSED, AND THEN HE PLUGGED THE CONTROL UNIT INTO A 20-AMPERE, 120-VOLT RECEPTACLE OUTLET. HE WENT TO THE CONTROL UNIT TO START THE ENFUSION PROCESS AND NOTICED THAT THERE WERE NO READINGS ON THE UNIT AND THAT THE PANEL WAS NOT LIT. HE TURNED THE RESET KNOB ON THE CONTROL UNIT, AND THE UNIT BLEW APART WITH A LOUD BOOM. THE EMPLOYEE WAS STRUCK IN THE FACE AND THE EYE BY THE CONTROL PANEL. HE WAS TAKEN TO A HOSPITAL, WHERE HE WAS TREATED FOR EYE DAMAGE AND RELEASED.
Keywords: E GI III, ELECTRICAL, ELECTRICAL FAULT, FLYING OBJECT, ELEC EQUIPMENT--MISC
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 107980435 | Non Hospitalized injury | Bruise/Contus/Abras | Plumbers, pipefitters and steamfitters |