Inspection: 107841371 - G And S Steel Erectors

Inspection Information - Office: Sc Department Of Labor, Licensing, And Regulation

 

Inspection Nr: 107841371
Report ID: 0454510
Date Opened: 11/20/1989

Site Address:
G And S Steel Erectors
Hood Rd
Greer, SC 29651

Mailing Address:
P. O. Box 921, Simpsonville, SC 29681

Union Status: NonUnion

SIC:1791

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 12/01/1989

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 03/20/1990


Related Activity
Type Activity Nr Safety Health
Accident 360282032
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 5 8
Current Violations 3 5 8
Initial Penalty $1,680 $0 $0 $0 $0 $1,680
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260021 B02 12/29/1989 01/04/1990 $0 $560 $0 I - Informal Settlement  
2. 01002 Serious 19260028 A 12/29/1989 01/04/1990 $0 $560 $0 I - Informal Settlement  
3. 01003 Serious 19260550 A15 I 12/29/1989 01/04/1990 $0 $560 $0 I - Informal Settlement  
4. 02001 Other 19260059 E01 12/29/1989 02/02/1990 $0 $0 $0 I - Informal Settlement  
5. 02002 Other 19260059 E01 I 12/29/1989 01/10/1990 $0 $0 $0 I - Informal Settlement  
6. 02003 Other 19260059 E02 12/29/1989 01/10/1990 $0 $0 $0 I - Informal Settlement  
7. 02004 Other 19260059 G01 12/29/1989 02/02/1990 $0 $0 $0 I - Informal Settlement  
8. 02005 Other 19260059 H 12/29/1989 02/02/1990 $0 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 675017
Event: 11/16/1989
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU BOOM

A CREW OF EMPLOYEES WAS ERECTING A STRUCTURAL STEEL BUILDING. THEY NEEDED TO GET SOME FLOOR DECKING THAT WAS STORED UNDER THREE PILES OF ROOF DECKING. THE CREW USED A PITTMAN HYDRALIFT (MODEL NO. HL1160; SERIAL NO. 24270-56327) TRUCK-MOUNTED CRANE TO MOVE THE ROOF DECKING. TWO EMPLOYEES RIGGED THE DECKING, AND THEY GUIDED IT WITH THEIR HANDS AS THE CRANE WAS MOVING IT. THEY HAD MOVED TWO PILES OF ROOF DECKING, AND THE EMPLOYEES WERE MOVING THE THIRD TO THE GROUND WHEN THE CRANE CAME TOO CLOSE TO A 44-KILOVOLT OVERHEAD POWER LINE. ONE OF THE TWO EMPLOYEES GUIDING THE LOAD WAS STANDING ON WET SOIL AND RECEIVED AN ELECTRIC SHOCK AND ELECTRICAL BURNS TO BOTH HANDS, TO BOTH FEET, AND TO HIS CHEST. HE WAS HOSPITALIZED FOR HIS INJURIES. THE CRANE OPERATOR, WHO LACKED TRAINING IN WORKING AROUND POWER LINES, HAD TAKEN THE CRANE CLOSER THAN 10 FEET TO THE LINE.

Keywords: BURN, OVERHEAD POWER LINE, ELECTRICAL, BOOM, CRANE BOOM, E C, ELECTRIC SHOCK, CRANE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 107841371 Hospitalized injury Electric Shock Structural metal workers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.