Powered by GoogleTranslate

Inspection Detail

Inspection: 107802332 - Pier Foundry & Pattern Shop Inc

Inspection Information - Office: Minnesota Department Of Labor And Industry

 

Inspection Nr: 107802332
Report ID: 0552700
Date Opened: 01/13/1988

Site Address:
Pier Foundry & Pattern Shop Inc
51 E. State St.
St. Paul, MN 55107

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3321

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/13/1988

Emphasis:

Case Closed: 04/26/1988


Related Activity
Type Activity Nr Safety Health
Accident 360316368
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $0 $0 $0 $0 $0 $0
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 52051220 02/19/1988 04/26/1988 $0 $0 $0 -  
2. 01002 Other 182065510 A 02/19/1988 04/26/1988 $0 $0 $0 P - Petition to Mod Abatement  

Investigation Summary

Investigation Nr: 998187
Event: 01/12/1988
ELECTRIC SHOCK AND BURN - DIRECT CONTACT WITH LIVE PARTS

AN EMPLOYEE WAS WORKING AS A FURNACE TENDER, OPERATING THE CONTROLS ON AN INDUCTIVE, TILT-POT, IRON MELTING FURNACE. THE CONTROLS FOR THE FURNACE WERE MOUNTED ON AN ENCLOSED PEDESTAL. BECAUSE OF A BROKEN COTTER PIN, THE POT-TILTING LEVER WOULD NOT ENGAGE. THE EMPLOYEE REMOVED THE SCREWS AND THE SIDE OF THE CONSOLE TO REPLACE THE COTTER PIN. HE HAD PERFORMED THIS PROCEDURE MANY TIMES BEFORE, BUT DID NOT KNOW THAT THE ELECTRIC POWER FOR CONTROLS IN THE CONSOLE COULD BE DEENERGIZED WITHOUT DEENERGIZING THE FURNACE. AS HE WAS TRYING TO REPLACE THE PIN, HE CROUCHED TO REACH UP INTO THE CONSOLE. HIS FOOT THEN SLIPPED, ALLOWING HIM TO FALL AGAINST A 120-VOLT TERMINAL BOARD. HE RECEIVED AN ELECTRIC SHOCK AND BURNS TO HIS SHOULDER. HE WAS TAKEN TO THE HOSPITAL, WHERE HE WAS TREATED AND RELEASED.

Keywords: BURN, CLOTHING, E GI IV, ELECTRICAL, SLIP, LOCKOUT, ELECTRIC SHOCK, ELECTRICAL CABINET

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 107802332 Non Hospitalized injury Burn/Scald(Heat) Furnace, kiln and oven operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.