Powered by GoogleTranslate

Inspection Detail

Inspection: 107705675 - St. Louis Southwestern Railway Co.

Inspection Information - Office: Little Rock Area Office

 

Inspection Nr: 107705675
Report ID: 0627100
Date Opened: 08/18/1993

Site Address:
St. Louis Southwestern Railway Co.
Bridge Point 217.77
Roe, AR 72134

Mailing Address:
1400 E. 2nd St., Pine Bluff, AR 71601

Union Status: Union

SIC:1629

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/24/1993

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 12/14/1993


Related Activity
Type Activity Nr Safety Health
Accident 360935670
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 2 6
Current Violations 2 2 4
Initial Penalty $14,400 $0 $0 $0 $0 $14,400
Current Penalty $9,000 $0 $0 $0 $0 $9,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260550 A01 11/02/1993 11/15/1993 $4,500 $4,500 $0 -  
2. 01002 Other 19260550 A02 11/02/1993 11/30/1993 $0 $3,150 $0 I - Informal Settlement Citation has been deleted.
3. 01003 Other 19260550 A06 11/02/1993 11/30/1993 $0 $2,250 $0 I - Informal Settlement Citation has been deleted.
4. 01004 Serious 19260550 B02 11/02/1993 11/08/1993 $4,500 $4,500 $0 -  
5. 02001 Other 19260350 A09 11/02/1993 11/30/1993 $0 $0 $0 -  
6. 02002 Other 19260351 B03 11/02/1993 11/15/1993 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 14497309
Event: 08/17/1993
Employee killed when struck by cable

A work crew raised a concrete cap to be placed onto a steel trestle. The total clearance was 34 inches between the top of the trestle and the bottom of the stringer. The cap was measured at 32 1/4 inches and 3/4 inch pads. Clearance was minimal. The north end of the cap contacted the stringer, but the south end was approximately 1 inch lower and needed to be raised to clear the trestle. The lift operator was directed to raise the south end the remaining inch. The top end plate failed at the north end. The freed cable struck Employee #1, inflicting fatal injuries and knocking him from the bridge. The south end failed at the lower end plate, allowing the cap to fall to the ground. The spreader bar was shop-made and had not been tested or rated.

Keywords: WORK RULES, CONCRETE PANEL, CONSTRUCTION, END PLATE, STRUCK BY, BRIDGE, SPREADER BAR

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 107705675 Fatality Fracture Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close