Inspection Detail
Inspection: 107572570 - Uec Equipment Company
Inspection Information - Office: Little Rock Area Office
Site Address:
Uec Equipment Company
2904 E. 9th, Sw Ark. Electric Coop.
Texarkana, AR 75502
Mailing Address:
P. O. Box 21480, Oklahoma City, OK 73156
Union Status: NonUnion
SIC:7359
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 01/16/1992
Emphasis:
Case Closed: 01/21/1992
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360438071 |
Investigation Summary
An employee had finished making repairs and adjustments on an aerial lift and was making a test run. During this test, a nut on the lower hydraulic cylinder shaft broke into two pieces, causing the bucket and boom to fall 6.1 to 7.6 meters. The employee fell from the bucket onto the concrete, resulting in his death.
Keywords: EQUIPMENT FAILURE, AERIAL LIFT, REPAIR, BOOM, FALL, FALL PROTECTION
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 107572570 | Fatality | Fracture | Not specified mechanics and repairers |