Inspection Detail
Inspection: 107505703 - Triad Drilling, Inc.
Inspection Information - Office: Oklahoma City Area Office
Site Address:
Triad Drilling, Inc.
5 Mi W, 3 Mi S
Laverne, OK 73843
Mailing Address:
301 N. 48th Street, Woodward, OK 73801
Union Status: NonUnion
SIC:1381
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 09/21/1990
Emphasis:
Case Closed: 03/13/1991
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360154306 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $720 | $0 | $0 | $0 | $0 | $720 |
| Current Penalty | $720 | $0 | $0 | $0 | $0 | $720 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100303 B01 | 10/10/1990 | 10/15/1990 | $720 | $720 | $0 | 10/22/1990 | - |
Investigation Summary
TWO EMPLOYEES, WITHOUT TRAINING OR EXPERIENCE, WERE ASSIGNED TO FIND A WORKING LIGHTING FIXTURE AND INSTALL IT ON THE SUBSTRUCTURE OF A TRIAD DRILLING RIG. THE EMPLOYEES CONNECTED THE UNGROUNDED CIRCUIT CONDUCTOR TO THE BLADE FOR THE EQUIPMENT GROUNDING CONDUCTOR ON THE ATTACHMENT PLUG OF AN APPLETON LIGHTING FIXTURE. WHEN ONE OF THE EMPLOYEES HELD THE METAL FIXTURE IN ONE HAND WHILE HE PLUGGED IT INTO A 30-AMPERE CIRCUIT WITH THE OTHER HAND, HE WAS ELECTROCUTED.
Keywords: E GI III, ELECTRICAL, ELECTROCUTED, ATTACHMENT PLUG, GROUND FAULT, EQUIPMENT GROUNDING, UNTRAINED
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 107505703 | Fatality | Electric Shock | Occupation not reported |
Translate