Inspection Detail
Inspection: 107452997 - R.W. Hultin Construction Co.
Inspection Information - Office: Springfield Area Office
Site Address:
R.W. Hultin Construction Co.
170 Sterling Rd.
Princeton, MA 01541
Mailing Address:
Millbury Rd., Oxford, MA 01540
Union Status: NonUnion
SIC:1794
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 12/03/1990
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 02/26/1991
Investigation Summary
While operating an excavator, Employee #1 struck a propane tank and ruptured its filler pipe, which then started to leak. Employee #1 tried to stop the leak by placing the excavator bucket against it. As a result, the propane seeped into the excavator where either the hot engine or the electrical system ignited the propane, causing a massive fireball. Employee #1's clothing caught on fire and he jumped from the excavator. A coworker managed to extinguish the fire. Employee #1 was taken to the hospital with severe burns.
Keywords: BURN, WORK RULES, FIRE, CONSTRUCTION, RUPTURE, COLLISION, EXCAVATOR, PIPE, PROPANE, TANK
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 107452997 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported |