Powered by GoogleTranslate

Inspection Detail

Inspection: 107437782 - Glyptal, Incorporated

Inspection Information - Office: Boston South Area Office

 

Inspection Nr: 107437782
Report ID: 0111400
Date Opened: 05/09/1991

Site Address:
Glyptal, Incorporated
305 Eastern Avenue
Chelsea, MA 02150

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:2851

NAICS: 0 


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 05/17/1991

Emphasis:

Case Closed: 08/05/1991


Related Activity
Type Activity Nr Safety Health
Referral 901756312 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 7 7
Current Violations 7 7
Initial Penalty $9,075 $0 $0 $0 $0 $9,075
Current Penalty $9,075 $0 $0 $0 $0 $9,075
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100106 D02 I 06/13/1991 06/26/1991 $1,575 $1,575 $0 -  
2. 01002 Serious 19100106 E02 IVC 06/13/1991 06/26/1991 $675 $675 $0 -  
3. 01003 Serious 19100106 E06 I 06/13/1991 06/19/1991 $900 $900 $0 -  
4. 01004 Serious 19100106 E06 II 06/13/1991 06/26/1991 $3,000 $3,000 $0 -  
5. 01005 Serious 19100132 A 06/13/1991 08/01/1991 $675 $675 $0 -  
6. 01006 Serious 19100157 G04 06/13/1991 08/01/1991 $675 $675 $0 -  
7. 01007 Serious 19101200 H02 IV 06/13/1991 08/01/1991 $1,575 $1,575 $0 -  

Investigation Summary

Investigation Nr: 170110027
Event: 05/09/1991
Employee injured in fire caused by xylene vapors

To clean a ceramic-lined paint ball mill, Employee #1 was pouring 2 to 3 gallons of xylene from an open 5 gallon, 26 gauge steel container into the port of the ball mill. The employee made contact between the cast iron skin of the ball mill and the steel can, which generated a static spark that caused an explosion and flash fire. The employee suffered third-degree burns to his left hand, wrist, and arm, and first-degree burns to his face and upper torso. He inhaled superheated vapors that damaged his lungs.

Keywords: BURN, LUNG, FLAMMABLE VAPORS, XYLENE, CLEANING, FIRE, INHALATION, EXPLOSION, SPARK, HAND

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 107437782 Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close