Inspection Detail
Inspection: 107353906 - Suffolk Industries Recovery Corp. Dba P.K. Metals
Inspection Information - Office: Long Island Area Office
Site Address:
Suffolk Industries Recovery Corp. Dba P.K. Metals
3542 Route 112
Coram, NY 11727
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:5093
NAICS: 0
Inspection Type: Referral
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 06/23/1993
Emphasis:
Case Closed: 08/04/1994
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 901922963 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 5 | 2 | 7 | |||
| Current Violations | 5 | 2 | 7 | |||
| Initial Penalty | $5,700 | $0 | $0 | $1,800 | $0 | $7,500 |
| Current Penalty | $3,420 | $0 | $0 | $1,080 | $0 | $4,500 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100110 E04 III | 09/10/1993 | 09/17/1993 | $630 | $1,050 | $0 | I - Informal Settlement | ||
| 2. | 01002 | Serious | 19100212 A03 II | 09/10/1993 | 09/17/1993 | $900 | $1,500 | $0 | I - Informal Settlement | ||
| 3. | 01003 | Serious | 19101200 E01 | 09/10/1993 | 10/13/1993 | $630 | $1,050 | $0 | I - Informal Settlement | ||
| 4. | 01004 | Serious | 19101200 G08 | 09/10/1993 | 09/28/1993 | $630 | $1,050 | $0 | I - Informal Settlement | ||
| 5. | 01005 | Serious | 19101200 H | 09/10/1993 | 10/13/1993 | $630 | $1,050 | $0 | I - Informal Settlement | ||
| 6. | 02001 | Other | 19030002 A01 | 09/10/1993 | 09/15/1993 | $180 | $300 | $0 | I - Informal Settlement | ||
| 7. | 02002 | Other | 19040002 A | 09/10/1993 | 10/13/1993 | $900 | $1,500 | $0 | I - Informal Settlement |
Investigation Summary
While Employee #1 dismantled and cut acetylene cylinders, an explosion occurred. Employee #1 was hospitalized. The cylinders were not properly purged of all gas.
Keywords: DISMANTLING, CYLINDER, FLAMMABLE VAPORS, ACETYLENE, GAS, EXPLOSION, CUTTING AND BURNING
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 107353906 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported |